Real-Khawvel Inbiakpawhna & System Commissioning Test

 

He video hian a rawn present alive system test leh inbiakpawhna commissioning te a awm bawkkan50kW Commercial & Industrial Energy khawlkhawmna tur a ni, a chhehvela sak a niGoodWe ET Series hybrid inverter hmanga siam a nileh ahigh-voltage lithium battery hmanga siam a ni.

 

Test hian a ngaihtuah ber a niinverter–battery hmanga inbiakpawhna nghet tak, system siam dan tur ruahmanna siam a ni, lehAPP hmanga real-time monitoring a ni, engineering lama kan theihna chak tak lantir nanESS inzawmkhawm, commissioning, leh quality control te a ni.

 

System Configuration chungchang thlirletna

 

  • Inverter hmanga siam a ni.A rilru a buai em em a, a rilru a hah em em bawk a. 50kW Three-Phase Hybrid Inverter
  • Battery hman dan tur: 1.1.High-Voltage Lithium Battery (102.4kWh class) hmanga siam a ni.
  • Dilna chi hrang hrang:Sumdawnna leh industry lama chakna khawlkhawm (C&I ESS) .
  • Operating Mode hrang hrang a thlawp:

○ Mahni-Consumption

○ Peak Shaving tih hi a ni

○ Backup / UPS-level-a inthlak danglamna

○ Grid-Tied & Off-Grid Hybrid hmanga hnathawh dan

page-1704-1279

 

He Video-in A Tilang

 

BMS–Inverter hmanga inbiakpawhna nghet tak

Inverter leh high-voltage battery te hi CAN protocol hmangin awlsam takin an inbiak a, hei hian SOC reading dik tak, charge/discharge control, leh system safety logic te a tichiang a ni.

01

Professional Commissioning kalpui dan tur

Kan engineer te hian system setup, parameter configuration, leh communication check te chu manufacturer standard leh international installation practices angin khauh takin an ti zo thin.

02

APP Monitoring & Remote atanga enkawl dan tur a ni

Real-time system data-power flow, battery status, leh operating mode telin-chu monitoring APP hmangin hlawhtling takin a lang a, a enkawl a, hei hian digital integration rintlak tak a nemnghet a ni.

03

System rintlak leh Engineering lama theihna

He test hian kan hands{0}}on experience a lantir a niGoodWe sumdawnna atana hman tur hybrid inverter te, high-voltage ESS solutions, leh a kim vekEPC-level system hmanga pek chhuah.

04

 

Kan Customer Tana Hei Hi A Pawimawh Chhan

 

Experience nei tawh tih finfiah tawhGoodWe 40–50kW ET Series hybrid inverter hmanga siam a ni

01

Thiamna chak tak inhigh-voltage battery system inzawmkhawmna a ni

02

Rintlakpre-delivery testing & quality tihchian a ni

03

A remchang hlefactory, warehouse, sumdawnna hmun, leh microgrid project te a awm bawk

04

A thlawp bawkenergy cost tihchangtlun, backup power, leh grid stability te a ni

05

 

 

Kan Inpekna

Kan thilpekte-kan supply mai mai lotest kim tawh, configure dik tak, leh application-ready energy storage solutions te a ni.


System tin hian an paltlang thininbiakpawhna testing, functional verification, leh monitoring validation te a nikan thawn chhuah hmain installation mumal tak leh hun rei tak-kan khawvel pum huapa kan thawhpui te tana rintlak a nih theih nan.